Al hacer clic en el botón de una pregunta.
Wire rope sling capacity chart in mm.
0 8 for spliced eyes.
Sling calculation using the breaking force of wire rope.
He end of a single wire rope is bent back along the wire rope to form the eye.
Rated capacities basket hitch based on d d ratio of 25.
Loop size 2 legs 3 legs 4 legs 60 45 30 60 45 30 60 45 30 6 x 19 xip iwrc 1 4 0 65 0 48 1 3 2 x 4 1 1 0 92 0 65 1 7 1 4 0 97 2 2 1 8.
Durante la prueba puede hacer clic en el botón revisar pregunta para marcar la pregunta en amarillo como un recordatorio visual para volver a visitar la pregunta antes de enviar las respuestas de la prueba.
Straight sling reeved sling max 60 basket sling max 60 mm 60 90 120.
Wll f min x k t z p x g where f min is the minimum breaking force of the rope kilonewtons.
Manila rope strength manila 3 strand rope minimum breaking.
Suerte en el test.
Wire rope sling capacity chart xlsx author.
K t is a factor which allows for the efficiency of the termination 0 9 for ferrule secured eyes.
Chain size straight sling adjustable.
Working load limit under general use with 1770 grade wire and wire rope core with ferrule secured eyes.
Wire rope slings using the general purpose body style are rugged economical and easy to inspect.
Vertical choker basket approx.
Single leg slings capacity tons multiple leg slings capacity tons rope dia.
8 40 2 0 78 0 58 0 39 1 56 1 35 1 10 0 78 78 0 68 0 55 0 39 1 35 1 10 0 78 1 01 0 68.
Miscellaneous engineering related topics like beaufort wind scale ce marking drawing standards and more.
Length tolerances single part wire rope slings standard length tolerance is plus or minus two rope diameters or plus or minus 0 5 of the sling length whichever is greater.
The 6 19 classification iwrc is a rugged general purpose wire rope used for most slings up through 1 1 8 size.
See page 91 for reduced choker capacity when using these hook sizes.
Slings with wire rope bodies larger than 1 1.
Rated capacities based on pin diameter no larger that natural eye width or less than the nominal sling diameter.
Elevator force and power required force and power to lift an elevator.
The splice makes a sling that can be easily pulled through narrow spaces because there are no rough ends to snag on loads.
Dia mm construction ungalvanised rope safe working load standard loop size eye inches dia mm 8 6 x 19 sc 650 kg 5 8 9 6 x 19 sc 800 kg 5 9 10 6 x 19 sc 1 00 mt 5 10 11 6 x 19 sc 1 20 mt 6 11 12 6 x 19 sc 1 40 mt 6 12.
Force and tension in rope due to angle reduced load capacity in ropes cables or lines due to angle.
Strands are hand tucked into the body of the rope in what is called a tapered and concealed splice.
No se preocupe el test no está medido en tiempo así que relájese y concéntrese en las preguntas y lo hará genial.
G is the factor relating mass to force and has the.